Thermal Expansion Data of Heated PCB Targets for IR Camera Calibration

Background

The aim of the dataset is to provide data on the expansion behaviour of FR4 and Rogers based printed circuit boards (PCB) under active embedded heating. The original pupose of the PCBs is the use as reference pattern with known geometrical features for thermal camera calibration as published here. To supply heat the PCBs embed a long narrow trace on the bottom side with a nominal resistance of 10 Ohm. An applied voltage to turns the trace into a joule heater. The top side is populated with a 21 x 21 dot grid pattern to track in plane distortions while thermal expansion. The dots are 1.5mm in diameter and spaced 4 mm apart. The resulting 80 x 80 mm pattern is centered on a PCB of size 100 x 100 mm. The thickness is 1.6 mm for all FR4 samples and 1.52 mm for all Rogers Samples. The heating trace is centered and covers 90 x 90 mm of each PCB.

Single Meaurements

The measurements were conducted by using a coordinate machine (Mahr OMS553HA). All poitns on the pcb were aquired by first moving the telecentric probing camera above each point of the grid pattern. Then a circle was fitted to the recorded image and the results were saved in four different files. Each file contains either the Location in X, Y or Z and the diameter of the fitted circle. The file format follows csv, but with tabstop (\t) as delimiter. Each value is stored as float string in mm.

X direction (in-plane):

``` File_X.txt

Pos_X_1,1 Pos_X_1,2 Pos_X_1,3 ... Pos_X_1,n
Pos_X_2,1 Pos_X_2,2 Pos_X_2,3 ... Pos_X_2,n
...       ...                 ...
Pos_X_n,1 Pos_X_n,2 Pos_X_2,3 ... Pos_X_2,n

```

Y direction (in-plane): ``` File_Y.txt

Pos_Y_1,1 Pos_Y_1,2 Pos_Y_1,3 ... Pos_Y_1,n
Pos_Y_2,1 Pos_Y_2,2 Pos_Y_2,3 ... Pos_Y_2,n
...       ...                 ...
Pos_Y_n,1 Pos_Y_n,2 Pos_Y_2,3 ... Pos_Y_2,n

```

Z direction (distance between PCB and optical probe):

``` File_Z.txt

...

```

D (diameter of the fitted circle):

``` File_D.txt

...

```

Directory Structure

All Measurments are stored in the data folder/ archive using the following directory pattern: Material / Heating Element Pattern / Applied Voltage / Sample ID / Measurement ID / Measurement_File_(X/ Y/ Z/ D).txt

Material: FR4 Rogers - RO4350B (Dk=3.48,Df=0.0037)

Material of the samples core

Heating Element Pattern: Meander Hilbert

The way the 10 Ohm trace was implemented. Either as Meander or as Hilbert curve. See design files for reference.

Applied Voltage: 00V 20V

The voltage which was supplied to the either "0 or 20 V (00V/20V). For selected samples there is more extensive data seperated and located in the step_input tracking the expansion of the PCBs over a non binary sequence of expiriments (0V -> 5V -> 10V ->15V -> 20V). Additionally the temprature directory hosts temprature data recorded by an Infratec Variocam HD Head 900 with further instructions.

Optional: step_input / temprature

Sample ID: i.e. 0204

Unique ID for every physical PCB

Measurement ID: i.e 00

Tracks the sequence of the measurements.

00 --> 01 --> 02 (Cold --> Hot --> Cold)

Data and Resources

Cite this as

Peter Shobowale, Lorenzo Ledesma, Markus Kästner (2026). Thermal Expansion Data of Heated PCB Targets for IR Camera Calibration [Data set]. LUIS. https://doi.org/10.25835/0pua6j2o
Retrieved: 13:02 19 Nov 2026 (UTC)

Additional Info

Field Value
Author Peter Shobowale, Lorenzo Ledesma, Markus Kästner
Maintainer Peter Shobowale
Version 1.0
Last Updated November 19, 2026, 10:03 (UTC)
Created November 12, 2026, 14:19 (UTC)
License Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International
Dataset Size 300.1 MByte